Welcome to visit Xinxiang Zhongxin Hydraulic Technology Co., Ltd. !
When the filter fails during use, it can be explained by the following reasons:
1. Deformation of the filter element: This fault is generally caused by the blockage of the filter element due to serious pollution during the working process, which in turn causes the pressure difference between the inflow and outflow filter element to become larger, so that the filter element is deformed due to insufficient resistance strength; The model of the selected filter element does not meet the requirements, which causes its operating pressure to exceed the pressure it can withstand, resulting in abnormal deformation.
2. Filter desoldering failure: This failure is generally caused by the fact that the operating temperature of the filter exceeds its tolerance temperature, or the welding is not strong, which leads to the phenomenon of desoldering when it is greatly impacted by the liquid.
3. Filter corrosion: If the acid-base level of the filter object exceeds its tolerance level, it will easily lead to abnormal corrosion, thereby affecting its normal use.
4. The filter is blocked: If the viscosity of the original material filtered by the filter is too large, or there are too many impurities, it may cause it to be blocked, thereby affecting its normal use.
2024.07.29